PERFORMANCE FEATURES: ◆ Original Mitsubishi intelligent power module assembly ◆ Frequency toroidal transformer, which makes the inverter has high efficiency and low no-load loss ◆Perfect protection and alarming function, thus the system has a high stability ◆ LCD display function, visually display battery voltageand AC output voltage ◆Pure sine wave output, compared with square wave or modified wave, has higher efficiency and higher loading capability ◆Adopts SCM to control, which makes the circuit structure simple, and the control method and control strategy more flexible ◆Optionalby-pass function ensures the continuity and stability of system operation ◆European CE certification TECHNICAL PARAMETERS:
Model |
WI50-48 |
WI50-96 |
WI50-120 |
WI50-220 |
WI50-240 |
Rated Output Capacity |
5kVA |
Rated Battery Voltage |
48VDC |
96VDC |
120VDC |
216VDC |
240VDC |
Over Voltage Shutoff |
68VDC |
136VDC |
170VDC |
306VDC |
340VDC |
Over Voltage Recovery |
66VDC |
132VDC |
165VDC |
297VDC |
330VDC |
Under Voltage Shutoff |
42VDC |
84VDC |
105VDC |
189VDC |
210VDC |
Under Voltage Recovery |
48VDC |
96VDC |
120VDC |
216VDC |
240VDC |
No Load Loss |
0.9A |
0.14A |
0.14A |
0.1A |
0.09A |
Output Wave Form |
Pure Sine Wave |
Display Mode |
LCD |
Display parameters |
Battery Voltage,Output Voltage,State parameters |
Cooling Mode |
Fan |
Rated Output Voltage |
380VAC |
Wave Distortion |
≤4% |
Output Frequency |
50/60 Hz±0.05Hz |
Dynamic Response |
5% |
Overload Capacity |
120%1min,150%10s |
Inverter Efficiency |
Maxmum 90% |
Noise(1m) |
≤40dB |
Insulating Strenght |
1500VAC,1min |
Protection Function |
Battery over voltage protection,Battery under voltage protection, Battery reverse-connection protection,Output over load protection, Output short circuit protection,Over temperature protection. |
Working Ambient Temperature |
-20~50℃ |
Working Altitude |
≤4000m |
Working Ambient Humidity |
0~90%, no condensing |
Model |
WI100-120 |
WI100-220 |
WI100-240 |
Rated Output Capacity |
10kVA |
Rated Battery Voltage |
120VDC |
216VDC |
240VDC |
Over Voltage Shutoff |
170VDC |
306VDC |
340VDC |
Over Voltage Recovery |
165VDC |
297VDC |
330VDC |
Under Voltage Shutoff |
105VDC |
189VDC |
210VDC |
Under Voltage Recovery |
120VDC |
216VDC |
240VDC |
No Load Loss |
1.04A |
0.55A |
0.5A |
Output Wave Form |
Pure Sine Wave |
Display Mode |
LCD |
Display parameters |
Battery Voltage,Output Voltage,State parameters |
Cooling Mode |
Fan |
Rated Output Voltage |
380VAC |
Wave Distortion |
≤4% |
Output Frequency |
50/60 Hz±0.05Hz |
Dynamic Response |
5% |
Overload Capacity |
120%1min,150%10s |
Inverter Efficiency |
Maxmum 90% |
Noise(1m) |
≤40dB |
Insulating Strenght |
1500VAC,1min |
Protection Function |
Battery over voltage protection,Battery under voltage protection, Battery reverse-connection protection,Output over load protection, Output short circuit protection,Over temperature protection. |
Working Ambient Temperature |
-20~50℃ |
Working Altitude |
≤4000m |
Working Ambient Humidity |
0~90%, no condensing |
Model |
WI200-220 |
WI200-240 |
Rated Output Capacity |
20kVA |
Rated Battery Voltage |
216VDC |
240VDC |
Over Voltage Shutoff |
306VDC |
340VDC |
Over Voltage Recovery |
297VDC |
330VDC |
Under Voltage Shutoff |
189VDC |
210VDC |
Under Voltage Recovery |
216VDC |
240VDC |
No Load Loss |
0.6A |
0.6A |
Output Wave Form |
Pure Sine Wave |
Display Mode |
LCD |
Display parameters |
Battery Voltage,Output Voltage,State parameters |
Cooling Mode |
Fan |
|
|